Total knee arthroplasty: posterior tibial slope influences the size but not the rotational alignment of the tibial component.

Petros IsmailidisValerie KremoAnnegret MündermannMagdalena Müller-GerblAndrej Maria Nowakowski
Published in: Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA (2020)
Differences in the posterior tibial slope should not contribute to a rotational malalignment when using the ATA to align the prosthetic tibial plateau. Although statistically significant, the change in ATA with increasing slope was negligible.