Login / Signup

Geographical Discrimination in Curcuminoids Content of Turmeric Assessed by Rapid UPLC-DAD Validated Analytical Method.

Amrit PoudelJitendra PandeyHyeong-Kyu Lee
Published in: Molecules (Basel, Switzerland) (2019)
A fast and reliable ultra-performance liquid chromatography-diode array detection method was developed and validated for the quantitative assessment of turmeric extracts from different geographical locations. Acclaim RSLC PolarAdvantage II column (2.2 μm, 2.1 × 100 mm) was used to analyze individual curcuminoids (curcumin, demethoxycurcumin and bisdemethoxycurcumin) from turmeric samples. The detection was done on ultraviolet absorbance at 425 nm and the column temperature was maintained at 45 °C. A mobile phase consisting of acetonitrile and water was found to be suitable for separation, at a flow rate of 1 mL/min with linear gradient elution. Linearity, specificity, precision, recovery and robustness were measured to validate the method and instrument. Under the described conditions, curcuminoids were collected within one minute. The calibration curve of each curcuminoid showed good linearity (correlation coefficient > 0.999). The relative standard deviations (RSD) of intra-day, inter-day precision and repeatability were less than 0.73%, 2.47% and 2.47%, respectively. In the recovery test, the accuracy ranged from 98.54%-103.91% with RSD values of less than 2.79%. The developed method was used for quantification of individual curcuminoids of turmeric samples. Analysis of turmeric samples from Nepal and South Korea revealed that curcuminoid content was related to geographical location. Turmeric cultivated in warmer climates were found to have higher curcumionoid content than turmeric samples from cooler climates, the southern part of Nepal was found to have two times higher content of curcuminoids than turmeric from the north.
Keyphrases