Proton stopping measurements at low velocity in warm dense carbon.
Sophia MalkoW CayzacV Ospina-BohórquezK BhutwalaM Bailly-GrandvauxChristopher McGuffeyR FedosejevsX VaisseauAn TauschwitzJ I ApiñanizDiego de LuisG GattiM HuaultJosé Antonio Pérez-HernándezS X HuAlexander J WhiteL A CollinsK NicholsP NeumayerG FaussurierJ VorbergerGiuseppe PrestopinoC VeronaJoão Jorge SantosD BataniF N BegL RosoLuca VolpePublished in: Nature communications (2022)
Ion stopping in warm dense matter is a process of fundamental importance for the understanding of the properties of dense plasmas, the realization and the interpretation of experiments involving ion-beam-heated warm dense matter samples, and for inertial confinement fusion research. The theoretical description of the ion stopping power in warm dense matter is difficult notably due to electron coupling and degeneracy, and measurements are still largely missing. In particular, the low-velocity stopping range, that features the largest modelling uncertainties, remains virtually unexplored. Here, we report proton energy-loss measurements in warm dense plasma at unprecedented low projectile velocities. Our energy-loss data, combined with a precise target characterization based on plasma-emission measurements using two independent spectroscopy diagnostics, demonstrate a significant deviation of the stopping power from classical models in this regime. In particular, we show that our results are in closest agreement with recent first-principles simulations based on time-dependent density functional theory.