A modified intrascleral intraocular lens fixation technique with fewer anterior segment manipulations: 27-gauge needle-guided procedure with built-in 8-0 absorbable sutures.
Yuan YangTeng-Teng YaoYa-Li ZhouYi-Xiao WangZhao-Yang WangPublished in: BMC ophthalmology (2019)
The 27-gauge needle-guided intrascleral IOL fixation technique with built-in 8-0 absorbable sutures is easy to perform with fewer anterior chamber manipulations and achieves both anatomical and optical stability.