Biomechanical Effects of Incisional Negative Wound Pressure Dressing: An Ex Vivo Model Using Human and Porcine Abdominal Walls.
Boris Jansen-WinkelnStefan NiebischUwe ScheuermannInes GockelMatthias MehdornPublished in: BioMed research international (2018)
Our ex vivo model of iNPWT in porcine and human abdominal wall could show reproducible measurements of pressures within the wounds in both types of tissue. As intrawound pressures did not increase in the same way as the applied negative pressure, we suggest that our results do not advocate the idea of using iNPWT for wound care especially as seroma evacuation remains insufficient.