Calculation of iris-claw IOL power for correction of late in-the-bag IOL complex dislocation.
Valentín HuervaFrancisco J AscasoIsabel CaralAndrzej GrzybowskiPublished in: BMC ophthalmology (2017)
Using A-115 for ultrasound biometry and A-115.7 for optical biometry and SRK/T formula, ±1.00 D of SE, is able to get near 100% of cases. Nevertheless, ±1.00 D of SE decreased to 80% of the cases when the enclavation is retropupilar.