Duration and onset of action of high dose U-500 regular insulin in severely insulin resistant subjects with type 2 diabetes.
Rupendra T ShresthaAnjali F KumarAbdisa TaddeseAmeer A KhowajaAmir MoheetEvan OlawskyLynn E EberlyElizabeth R SeaquistPublished in: Endocrinology, diabetes & metabolism (2018)
The duration of action of U-500 increases when dose is increased from 100 to 200 units. Neither dose of U-500 insulin has an onset of action before 2.5 hours after administration. This suggests that U-500 should not be used as a premeal bolus insulin to lower glucose two hours after a meal and that dosing intervals might need to be extended as dose is increased to avoid hypoglycaemia.