Computed tomography derived predictors of permanent pacemaker implantation after transcatheter aortic valve replacement: A meta-analysis.
Oliver MaierKerstin PiaydaShazia AfzalAmin PolzinRalf WestenfeldChristian JungTobias ZeusGerald AntochMalte KelmVerena VeulemansPublished in: Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions (2021)
Besides the well-known impact of electrocardiographic and procedure-related factors on conduction disturbances, MSCT derived distribution of the aortic valve and left ventricular outflow tract calcification, as well as membranous septum length, are associated with an increased risk of PPI following TAVR.
Keyphrases
- transcatheter aortic valve replacement
- aortic valve
- aortic stenosis
- left ventricular
- aortic valve replacement
- transcatheter aortic valve implantation
- computed tomography
- positron emission tomography
- heart failure
- left atrial
- ejection fraction
- magnetic resonance imaging
- minimally invasive
- hypertrophic cardiomyopathy
- contrast enhanced
- protein protein
- vena cava
- acute coronary syndrome
- coronary artery disease
- inferior vena cava
- small molecule