Outcomes of Idiopathic Full-Thickness Macular Hole Surgery: Comparing Two Different ILM Peeling Sizes.
Alireza KhodabandeAlireza MahmoudiHooshang FaghihiFatemeh BazvandEbrahim EbrahimiHamid Riazi-EsfahaniPublished in: Journal of ophthalmology (2020)
In patients with idiopathic full-thickness macular hole (MHI ≤ 0.5), a larger ILM peel of 4 DD appears to yield better anatomical outcomes than a more limited 2 DD peel.