Login / Signup

Shear bond strength of resin-modified glass ionomer cement bound to mineral trioxide aggregate after various disinfection protocols.

Deniz YanıkKürşat ErAlper Kuştarci
Published in: Australian endodontic journal : the journal of the Australian Society of Endodontology Inc (2022)
This study compared the effects of 3 different cavity disinfection protocols (CDP) on the shear bond strength (SBS) of resin-modified glass ionomer cement (RM-GIC) to mineral trioxide aggregate (MTA). One hundred eighty standard holes were prepared and filled with MTA. They then divided into 3 main groups based on the chosen time intervals (15 min, 24 h, and 72 h). Main groups were divided into 3 subgroups based on the CDP [chlorhexidine gluconate (CHX), ozone, laser, and control]. RM-GIC was applied on MTA after CDP for all groups. A universal testing device was then used for test and the data was statistically analysed. CHX showed significantly lower SBS values except ozone and laser than the control (p < 0.05). There were no statistically significant differences among the time intervals. As a result, CHX decreased the bond strength between the MTA and RM-GIC while ozone and laser had no negative effect.
Keyphrases
  • particulate matter
  • drinking water
  • hydrogen peroxide
  • high speed
  • air pollution
  • big data
  • machine learning
  • high resolution
  • surgical site infection