Transseptal puncture for left atrial ablation: Risk factors for cardiac tamponade and a proposed causative classification system.
Edd MacleanKarishma MahtaniMarina RoelasRohan VyasCharles ButcherNikhil AhluwaliaShohreh HonarbakhshAntonio CretaMalcolm FinlayAnthony ChowMark EarleySimon SportonMartin LoweVinit SawhneyVivienne EzzatSyed AhsanFakhar KhanMehul DhinojaPier LambiaseRichard SchillingRoss HunterOliver SegalPublished in: Journal of cardiovascular electrophysiology (2022)
During left atrial ablation, the risk of TRCT was reduced by operator experience, TOE-guidance, and use of a transseptal guidewire, and was increased by patient age, re-do procedures, and failure to cross the septum first pass.