Comparison of thrombogenicity in different types of drug-eluting stents during transition from DAPT to SAPT.
Kenji KawaiYu SatoAnne CornelissenFrank D KolodgieQi ChengRika KawakamiTakao KonishiLaura E L PerkinsRenu VirmaniAloke V FinnPublished in: Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions (2024)
No evidence of rebound effect was seen after the transition from DAPT to SAPT. FP-EES demonstrated the most favorable antithrombotic and anti-inflammatory profile regardless of the different experimental designs.