Login / Signup

High-performance flexible metal-on-silicon thermocouple.

Daniel AssumpcaoShailabh KumarVinayak NarasimhanJongho LeeHyuck Choo
Published in: Scientific reports (2018)
We have demonstrated metal-on-silicon thermocouples with a noticeably high Seebeck coefficient and an excellent temperature-sensing resolution. Fabrication of the thermocouples involved only simple photolithography and metal-liftoff procedures on a silicon substrate. The experimentally measured Seebeck coefficient of our thermocouple was 9.17 × 10-4 V/°K, which is 30 times larger than those reported for standard metal thin-film thermocouples and comparable to the values of alloy-based thin-film thermocouples that require sophisticated and costly fabrication processes. The temperature-voltage measurements between 20 to 80 °C were highly linear with a linearity coefficient of 1, and the experimentally demonstrated temperature-sensing resolution was 0.01 °K which could be further improved up to a theoretical limit of 0.00055 °K. Finally, we applied this approach to demonstrate a flexible metal-on-silicon thermocouple with enhanced thermal sensitivity. The outstanding performance of our thermocouple combined with an extremely thin profile, bending flexibility, and simple, highly-compatible fabrication will proliferate its use in diverse applications such as micro-/nanoscale biometrics, energy management, and nanoscale thermography.
Keyphrases
  • diffusion weighted imaging
  • low cost
  • single molecule
  • magnetic resonance imaging
  • computed tomography
  • electron microscopy