Login / Signup

Long-term Continuous Glucose Monitor Use in Very Young Children With Type 1 Diabetes: One-Year Results From the SENCE Study.

Michelle A Van NameLauren G KanapkaLauren G KanapkaKellee M MillerAnastasia Albanese-O'NeillPersis V CommissariatSarah D CorathersKara R HarringtonMarisa E HilliardBarbara J AndersonJennifer C KelleyLori M B LaffelSarah A MacLeishBrandon M NathanWilliam V TamborlaneR Paul WadwaSteven M WilliKristen M WilliamsKupper A WintergerstStephanie WoernerJenise C WongDaniel J DeSalvo
Published in: Journal of diabetes science and technology (2022)
Over 12 months young children with T1D using newer CGM technology sustained reductions in hypoglycemia and, in contrast to prior studies, persistently wore CGM. However, pervasive hyperglycemia remained unmitigated. This indicates an urgent need for further advances in diabetes technology, behavioral support, and diabetes management educational approaches to optimize glycemia in young children.
Keyphrases
  • type diabetes
  • glycemic control
  • cardiovascular disease
  • blood glucose
  • magnetic resonance
  • insulin resistance
  • metabolic syndrome
  • blood pressure