MicroPulse Transscleral Laser Therapy Demonstrates Similar Efficacy with a Superior and More Favorable Safety Profile Compared to Continuous-Wave Transscleral Cyclophotocoagulation.

Enrico BernardiMarc Töteberg-Harms
Published in: Journal of ophthalmology (2022)
MP-TLT was as effective in lowering IOP as CW-TSCPC and achieved comparable success. Additionally, MP-TLT demonstrated consistent and effective outcomes at every time point. The improved safety profile of MP-TLT allows the therapeutic spectrum to be broadened, granting ophthalmologists' treatment of glaucoma in earlier stages of glaucoma than those typically treated with CW-TSCPC, i.e., early to moderate and to patients with good central-vision.
Keyphrases
  • optic nerve
  • high intensity
  • cataract surgery
  • replacement therapy
  • insulin resistance