Login / Signup

Strategies to optimize bonding of adhesive materials to molar-incisor hypomineralization-affected enamel: A systematic review.

Marianne LagardeElsa VennatJean-Pierre AttalElisabeth Dursun
Published in: International journal of paediatric dentistry (2020)
Bond strength of composite was not significantly different when using self-etch compared with etch-and-rinse adhesives. Deproteinization after etching for etch-and-rinse adhesives enhanced bond strength; this could allow to keep MIH-affected enamel. Icon® showed an erratic penetration; however, a preliminary deproteinization after etching could improve bond strength. A study reported no significant differences in sealant retention rate, whereas another recommended to previously apply an adhesive.