Login / Signup

Precontouring Plates for MIS Bilateral Femur Osteosynthesis Using a Patient-Specific 3D Printed Model: A Case Report.

Stephanus Johannes Van DeventerJoshua Qua HiansenChristopher KimAzad MashariMichael G Zywiel
Published in: JBJS case connector (2022)
3D printed models aided in precontouring fixation plates in a case with challenging bony anatomy, enabling minimally invasive surgery.
Keyphrases
  • minimally invasive
  • case report