Estimation of the temperature field in laser-induced hyperthermia experiments with a phantom.

Bernard LamienHelcio R B OrlandeLeonardo Antonio Bermeo VarónRodrigo Leite Queiroga BastoGuillermo Enrique EliçabeDilson Silva Dos SantosRenato Machado Cotta
Published in: International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group (2018)
This article demonstrated that the Particle Filter method can be used to accurately predict the temperatures in regions where measurements are not available. The present technique has potential applications in hyperthermia treatments as an observer for active control strategies, as well as to plan personalized heating protocols.
Keyphrases
  • image quality
  • magnetic resonance imaging
  • magnetic resonance
  • computed tomography
  • risk assessment