CT of the Larynx: Is an Additional High-Resolution Acquisition Necessary for Diagnostic Accuracy?
Eva ChauKatie S TraylorBarton F BranstetterPublished in: AJNR. American journal of neuroradiology (2023)
Reformatted images from our institution's standard neck CT acquisition were less accurate than dedicated images of the larynx for analysis of laryngeal tumor extension. Focused images of the larynx were needed to optimize interpretation.