Comparing outcomes of general anesthesia and monitored anesthesia care during transcatheter aortic valve replacement: The Cleveland Clinic Foundation experience.
Yasser SammourJimmy L KerriganKinjal BanerjeeRama Dilip GajulapalliHassan Mehmood LakSanchit ChawlaKrystof AndressNeha GuptaShinya UnaiLars G SvenssonJames YunGrant W ReedAndrej AlfirevicShiva SaleAnand MehtaAmar KrishnaswamyNikolaos SkubasSamir R KapadiaPublished in: Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions (2021)
Utilizing MAC and omitting intraprocedural transesophageal echocardiography during TAVR seems to be more efficient without compromising safety. Better TAVR outcomes can be achieved with newer generation valves without needing GA.