An Analysis of Ocular Biometrics: A Comprehensive Retrospective Study in a Large Cohort of Pediatric Cataract Patients.
Luca SchwarzenbacherLorenz WassermannSandra Rezar-DreindlGregor Sebastian ReiterUrsula Schmidt-ErfurthEva StifterPublished in: Journal of clinical medicine (2024)
Objectives: This study aims to provide a comprehensive analysis of ocular biometric parameters in pediatric patients with cataracts to optimize surgical outcomes. By evaluating various biometric data, we seek to enhance the decision-making process for intraocular lens (IOL) placement, particularly with advanced technologies like femtosecond lasers. Methods: This retrospective comparative study included pediatric patients with cataracts who underwent ocular biometric measurements and cataract extraction with anterior vitrectomy at the Medical University of Vienna between January 2019 and December 2021. Parameters measured included corneal diameter (CD), axial length (AL), corneal thickness (CT) and flat and steep keratometry (Kf and Ks). The study explored the correlations between these parameters and IOL placement. Results: A total of 136 eyes from 68 pediatric patients were included in the study. Significant positive correlations were found between corneal diameter, age and AL. The mean CD was 11.4 mm, mean AL was 19.5 mm, CT was 581.2 ± 51.8 µm, Kf was 7.76 ± 0.55 mm and Ks 7.41 ± 0.59 mm, respectively. Older pediatric patients with larger corneal diameters and longer ALs were more likely to receive in-the-bag IOL implantation. Conversely, younger patients often required alternative IOL placements or remained aphakic. Our data indicated that over 95% of the study population and all patients aged one year and older had a corneal diameter of 10 mm or larger. Conclusions: Detailed ocular biometric analysis is crucial for optimizing both surgical outcomes and postoperative care in pediatric cataract patients. The positive correlations between CD, age and AL underline the importance of individualized surgical planning tailored to each patient's unique anatomical features. Additionally, our findings suggest that the use of a femtosecond laser is both feasible and safe for pediatric patients aged one year and older, potentially offering enhanced surgical precision and improved outcomes.
Keyphrases
- end stage renal disease
- ejection fraction
- newly diagnosed
- chronic kidney disease
- optical coherence tomography
- prognostic factors
- decision making
- palliative care
- optic nerve
- computed tomography
- quality improvement
- machine learning
- cataract surgery
- patient reported outcomes
- contrast enhanced
- insulin resistance
- electronic health record
- deep learning
- big data
- patients undergoing
- pet ct