Nanoporous Carbon Immunosensor for Highly Accurate and Sensitive Clinical Detection of Glial Fibrillary Acidic Protein in Traumatic Brain Injury, Stroke, and Spinal Cord Injury.
Sultan KhetaniRazieh SalahandishJason B TaborMatthew ChilversSean DukelowChester HoChristina CampbellArindom SenChantel T DebertAmir Sanati NezhadPublished in: ACS biomaterials science & engineering (2023)
Elevated glial fibrillary acidic protein (GFAP) in the blood serum is one of the promising bodily fluid markers for the diagnosis of central nervous system (CNS) injuries, including traumatic brain injury (TBI), stroke, and spinal cord injury (SCI). However, accurate and point-of-care (POC) quantification of GFAP in clinical blood samples has been challenging and yet to be clinically validated against gold-standard assays and outcome practices. This work engineered and characterized a novel nanoporous carbon screen-printed electrode with significantly increased surface area and conductivity, as well as preserved stability and anti-fouling properties. This nano-decorated electrode was immobilized with the target GFAP antibody to create an ultrasensitive GFAP immunosensor and quantify GFAP levels in spiked samples and the serum of CNS injury patients. The immunosensor presented a dynamic detection range of 100 fg/mL to 10 ng/mL, a limit of detection of 86.6 fg/mL, and a sensitivity of 20.3 Ω mL/pg mm 2 for detecting GFAP in the serum. Its clinical utility was demonstrated by the consistent and selective quantification of GFAP comparable to the ultrasensitive single-molecule array technology in 107 serum samples collected from TBI, stroke, and SCI patients. Comparing the diagnostic and prognostic performance of the immunosensor with the existing clinical paradigms confirms the immunosensor's accuracy as a potential complement to the existing imaging diagnostic modalities and presents a potential for rapid, accurate, cost-effective, and near real-time POC diagnosis and prognosis of CNS injuries.
Keyphrases
- label free
- traumatic brain injury
- spinal cord injury
- sensitive detection
- end stage renal disease
- single molecule
- loop mediated isothermal amplification
- high resolution
- newly diagnosed
- ejection fraction
- atrial fibrillation
- neuropathic pain
- high throughput
- chronic kidney disease
- healthcare
- prognostic factors
- blood brain barrier
- quantum dots
- primary care
- spinal cord
- ionic liquid
- living cells
- gold nanoparticles
- small molecule
- severe traumatic brain injury
- patient reported outcomes
- real time pcr
- high speed
- patient reported
- fluorescent probe