Fibre-Cement Panel Ventilated Façade Smart Control System.
Anna Adamczak-BugnoGrzegorz ŚwitAleksandra KrampikowskaPublished in: Materials (Basel, Switzerland) (2021)
This paper outlines a design for a fibre-cement panel ventilated façade smart control system based on the acoustic emission method. The paper also provides methodology and test results, as well as statistical analysis of the three-point bending results with AE signal acquisition as a basis for the development of the system in question. The test items were samples cut from a full-size fibre-cement panel for interior and exterior use, according to the standard guidelines. The recorded acoustic emission signals were classified statistically into four classes, which were assigned to the processes occurring in the material structure as a result of the applied load. The system development was based on the differences between the characteristics of the individual signal classes and their number for each test case, as well as on the different distribution of successive classes over time. Given the results of the tests and the resulting conclusions indicating the applicability of the acoustic emission method (based on signal classification using the k-means algorithm for the assessment of variations in the mechanical parameters of cement-fibre composites), a methodology for such assessment was therefore developed. The approach proposed is a reasonable method for assessing the variation in mechanical parameters of fibre-cement panels on the basis of the parameters determined by the non-destructive method indicated.