Login / Signup

Hydrodynamic Characterization of Phase Separation in Devices with Microfabricated Capillaries.

Anand Narayanan Pallipurath RadhakrishnanMarc PradasEva SorensenSerafim KalliadasisAsterios Gavriilidis
Published in: Langmuir : the ACS journal of surfaces and colloids (2019)
Capillary microseparators have been gaining interest in downstream unit operations, especially for pharmaceutical, space, and nuclear applications, offering efficient separation of two-phase flows. In this work, a detailed analysis of the dynamics of gas?liquid separation at the single meniscus level helped to formulate a model to map the operability region of microseparation devices. A water?nitrogen segmented flow was separated in a microfabricated silicon-glass device, with a main channel (width, W = 600 ?m; height, H = 120 ?m) leading into an array of 276 capillaries (100 ?m long; width = 5 ?m facing the main channel and 25 ?m facing the liquid outlet), on both sides of the channel. At optimal pressure differences, the wetting phase (water) flowed through the capillaries into the liquid outlet, whereas the nonwetting phase (nitrogen) flowed past the capillaries into the gas outlet. A high-speed imaging methodology aided by computational analysis was used to quantify the length of the liquid slugs and their positions in the separation zone. It was observed that during stable separation, the position of the leading edge of the liquid slugs (advancing meniscus), which became stationary in the separation zone, was dependent only on the outlet pressure difference. The trailing edge of the liquid slugs (receding meniscus) approached the advancing meniscus at a constant speed, thus leading to a linear decrease of the liquid slug length. Close to the liquid-to-gas breakthrough point, that is, when water exited through the gas outlet, the advancing meniscus was no longer stationary, and the slug lengths decreased exponentially. The rates of decrease of the liquid slug length during separation were accurately estimated by the model, and the calculated liquid-to-gas breakthrough pressures agreed with experimental measurements.
Keyphrases
  • ionic liquid
  • liquid chromatography
  • room temperature
  • epithelial mesenchymal transition
  • high resolution
  • photodynamic therapy