A comparison of 3-D CT and 2-D plain radiograph measurements of the wrist in extra-articular malunited fractures of the distal radius.

Camiel J SmeesEline M van EsGabriëlle J M TuijthofJoost W ColarisFeike de GraaffAnne J H Vochteloo
Published in: The Journal of hand surgery, European volume (2023)
Two-dimensional (2-D) plain radiographs may be insufficient for the evaluation of distal radial malunion, as it is a three-dimensional (3-D) deformity. This study introduced a 3-D measuring method that outputs radial inclination, ulnar variance, palmar tilt and axial rotation. To this end, a standardized and clearly defined coordinate system was constructed that allowed 3-D measurements closely resembling the conventional 2-D method in 35 patients. Mean differences between 3-D and 2-D measurements in affected wrists were 1.8° for radial inclination, 0.8 mm for ulnar variance and 3.7° for palmar tilt. In addition, inter- and intra-observer reproducibility of all 3-D and 2-D measurements were good or excellent (intraclass correlation coefficient >0.75), with 3-D reproducibility always better than 2-D. Axial rotation was present in all patients with a mean of 7.9° (SD 6.9). Although the differences between 2-D and 3-D measurements were small, 3-D evaluation enables the assessment of axial rotation and brings us closer to a routine 3-D evaluation of malunion. Level of evidence: III.