The potential of piR-823 as a diagnostic biomarker in oncology: A systematic review.
Eun Jung SohnMyoung-Eun HanYoung Mok ParkYun Hak KimSae-Ock OhPublished in: PloS one (2023)
The area under the curve (AUC) values of 26 piRNAs in patients with cancer ranged from 0.624 to 0.978, with piR-9491 showing the highest value (0.978). The sensitivity of the total of 21 piRNAs in cancer patients was between 42.86 and 100, with piR-9491 showing the highest sensitivity (100). The specificity of these 21 piRNAs ranged from 60.10 to 96.67 (with piR-018569 showing the highest specificity (96.67)). Their odds ratios were between 1.61 and 44.67, and piR-12488 showed the highest odds ratio (44.67). Generally, the piRNAs in this review showed better sensitivity and AUC values than current clinical diagnostic biomarkers, although current biomarkers appear to be more specific. Reviewed piRNAs showed better diagnostic performance than currently used clinical biomarkers. Notably, piR-823 showed a significant diagnostic performance in four types of cancer (colorectal, esophageal, gastric, and renal cell cancer). However, all 18 studies included in this review were a case-control study. So, further prospective studies are required for their validation.