Our findings suggest standard prophylactic anticoagulation dosing risks underdosing and therefore, an increased risk in the development of VTE. AFXa monitoring allows individually tailored dose adjustment to reach therapeutic levels, which may be efficacious in reducing VTE events and is therefore recommended where possible.