Login / Signup

Evolution and prognosis of tricuspid and mitral regurgitation following cardiac implantable electronic devices: a systematic review and meta-analysis.

Matthew F YuyunJacob JosephSebhat A ErqouScott KinlayJustin Basile Echouffo-TcheuguiAdelqui O PeraltaPeter S HoffmeisterWilliam E BodenHirad YarmohammadiDavid T MartinJagmeet P Singh
Published in: Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology (2024)
Our findings suggest that, when possible, adoption of pacing strategies that avoid isolated trans-tricuspid RV leads may be beneficial in preventing incident or deteriorating atrioventricular valvular regurgitation and might reduce mortality.
Keyphrases