Correlation between Polysomnographic Parameters and Tridimensional Changes in the Upper Airway of Obstructive Sleep Apnea Patients Treated with Mandibular Advancement Devices.
Sara Camañes-GonzalvoRocío Marco-PitarchAndrés Plaza-EspínJavier Puertas-CuestaRuben Agustin-PanaderoAntonio Fons-FontCarla Fons-BadalMarina García-SelvaPublished in: Journal of clinical medicine (2021)
The mandibular advancement device used was found to be effective in improving polysomnographic parameters. Moreover, the oral appliance was able to significantly increase the tridimensional dimensions of the upper airway. Moreover, this finding was correlated with a reduction in the apnea hypopnea index (p = 0.007) and an increase on minimum oxygen saturation (p = 0.033).