Computer-aided diagnosis system for thyroid nodules on ultrasonography: diagnostic performance and reproducibility based on the experience level of operators.
Eun Young JeongHye Lin KimEun Ju HaSeon Young ParkYoon Joo ChoMiran HanPublished in: European radiology (2018)
• The sensitivity and accuracy of the CAD system did not differ significantly from those of the experienced radiologist (88.6% vs. 84.1%, p = 0.687; 86.0% vs. 91.0%, p = 0.267) while the specificity was significantly higher for the experienced radiologist (83.9% vs. 96.4%, p = 0.016). • However, the diagnostic performance varied according to the operator's experience (sensitivity 70.5-88.6%, accuracy 72.0-86.0%) and they were lower for the less-experienced operators than for the experienced radiologist. • The interobserver agreement was substantial for the final diagnosis and each US descriptor and moderate for the margin and composition.