Login / Signup

Volume Percentage of Filling Voids in Root Canals Prepared by a Novel Nickel-Titanium Rotary System (TruNatomy) Using Two Different Obturation Techniques.

You Jin LeeSunil KimSu-Jung Shin
Published in: Materials (Basel, Switzerland) (2021)
This study aimed to compare the volume percentage of filling voids in root canals prepared with a newly introduced rotary system, TruNatomy (Dentsply Maillefer), and obturated by the modified continuous wave (CW) or single cone (SC) filling technique. Plastic tooth models with four canals were enlarged by using TruNatomy files and randomly allocated into either the CW or SC group. The volume percentage of filling voids at 1-6 mm from the apex was analyzed by using microcomputed tomography; mean values were compared by using independent two-sample t-tests (p < 0.05). The mean volume percentages of the filling voids were 2.81 ± 1.11% and 1.77 ± 0.82% in the CW and SC groups, respectively. In the apical area (1-4 mm), volume percentages in the palatal were significantly different between the CW and SC groups; in the middle area (4-6 mm), volume percentages in the palatal and the second mesiobuccal canals were significantly different (p < 0.05). The SC group showed lower volume percentages of filling voids than the CW group. The canals prepared by the TruNatomy system can be obturated well by both the SC and CW techniques. The SC technique showed a lower number of voids, especially in the palatal canals.
Keyphrases
  • cone beam