Cold Pulsatile Machine Perfusion versus Static Cold Storage in Kidney Transplantation: A Single Centre Experience.
Maria Irene BelliniSotiris CharalampidisPaul Elliot HerbertVasileios BonatsosJeremy CraneAnand MuthusamyFrank J M F DorVassilios PapaloisPublished in: BioMed research international (2019)
HMP decreased DGF compared to CS, offering viability assessment pretransplant and improving one-year renal function of the grafts.