Achieving high convective volume in hemodiafiltration: Lessons learned after successful implementation in the HDFit trial.
Murilo GuedesAna Claudia DambiskiSinaia CanhadaAna Beatriz L BarraCarlos Eduardo Poli-de-FigueiredoAmérico Lourenço Cuvello NetoMaria Eugênia F CanzianiJorge Paulo Strogoff-de-MatosJochen G RaimannJohn LarkinBernard CanaudRoberto Pecoits-Filhonull nullPublished in: Hemodialysis international. International Symposium on Home Hemodialysis (2020)
High-volume online hemodiafiltration was successfully implemented with 99% of patients achieving protocol defined CV target. Monthly mean CV was consistently >22 L/treatment during follow-up. Kt/V increased, and phosphate decreased with OL-HDF. Findings resulting from a short training period in several dialysis facilities appear to suggest HDF is an easily implementable technique.