Login / Signup

RSNA and BSTI grading systems of COVID-19 pneumonia: comparison of the diagnostic performance and interobserver agreement.

Seyhmus KavakRecai Duymus
Published in: BMC medical imaging (2021)
As a result, RSNA and BSTI statement provided reasonable performance and interobservers agreement in reporting CT findings of COVID-19. However, the number of patients defined as false negative and indeterminate in both classification systems is at a level that cannot be neglected.
Keyphrases