Posture-Induced Intraocular Pressure Changes after iStent Inject W Combined with Phacoemulsification in Open Angle Glaucoma Patients.

Kentaro IwasakiShogo ArimuraYusuke OriiMasaru Inatani
Published in: Medicina (Kaunas, Lithuania) (2023)
Background and Objectives : The purpose of this study was to evaluate the posture-induced intraocular pressure (IOP) changes after iStent inject W combined with phacoemulsification procedure in Japanese patients with open-angle glaucoma. Materials and Methods : We prospectively evaluated the posture-induced IOP changes after surgery. The primary outcome was the posture-induced IOP changes postoperatively. Secondary outcome measures included postoperative complications, visual acuity, visual field, and corneal endothelial cell density. Results : This study completed the prospective observation for 15 eyes (15 patients). The mean preoperative IOP with the Goldmann applanation tonometer was 16.0 ± 2.6 mm Hg with a mean glaucoma medication usage of 2.5 ± 1.2, which decreased to 14.4 ± 2.4 mm Hg ( p = 0.14) and 0.5 ± 0.9 medications ( p < 0.01), respectively, 12 months postoperatively. The mean baseline IOP with the ICare was 12.0 ± 2.7 mmHg in the sitting position, which significantly increased to 15.2 ± 3.8 mmHg in the lateral decubitus position ( p < 0.01). This postural IOP difference was 3.2 ± 2.2 mmHg and 3.2 ± 2.4 mmHg at baseline and 12 months postoperatively, respectively, with no significant changes ( p > 0.99). Conclusions : iStent inject W combined with cataract surgery reduced the IOP and the number of glaucoma medications during short-term follow-ups with high safety. However, iStent inject W did not affect the degree of posture-induced IOP changes.