Login / Signup

Comparison of heparinized saline and 0.9% sodium chloride for maintaining central venous catheter patency in healthy dogs.

Julieann VoseAdesola OdunayoJoshua M PriceMaggie DavesJulie C SchildtMary Katherine Tolbert
Published in: PeerJ (2019)
All CVCs in both groups were patent after 72 h, which was demonstrated by aspiration of blood and ease of flushing the catheter. Two CVCs in the 0.9% sodium chloride group had a negative aspiration at hour 12 and 36, respectively. One CVC in the HS group had a negative aspiration at hour 18. Signs of phlebitis occurred in three dog: two in the 0.9% sodium chloride group and one in the HS group. No dog was hyperthermic (>103 °F). Two catheters were inadvertently removed by dogs in the HS group during the study. There were no significant differences in catheter patency, incidence of phlebitis, or incidence of negative aspirations between both groups. aPTT and PT values remained within the normal reference range for all dogs in both groups. Ultimately, 0.9% sodium chloride was as effective as 10 IU/mL HS in maintaining the patency of CVCs for up to 72 h in healthy dogs. Further evaluation in clinical patients is warranted.
Keyphrases
  • ultrasound guided
  • end stage renal disease
  • blood pressure
  • risk factors
  • chronic kidney disease
  • peritoneal dialysis