Variability in insulin pharmacokinetics following high-dose insulin therapy.
Darren M RobertsHaddijatou K HughesPaul Steven HaberGraham R D JonesPublished in: Clinical toxicology (Philadelphia, Pa.) (2021)
Markedly different insulin pharmacokinetics post-HDI is observed in two cases and a previously published report, and factors contributing to the interpatient differences are poorly defined. This pharmacokinetic variability impacts on the severity and duration of treatable hypoglycemia post-HDI. Analytical factors impacting on the measured plasma insulin concentrations include appropriate sample dilution and differing analytical specificity for the type of insulin.