Biomechanical Study of the Osteoporotic Spine Fracture: Optical Approach.
Mircea SoponValentin OleksikMihai RomanNicolae CofaruMihaela OleksikCosmin MohorAdrian BoiceanSorin-Radu FleacăPublished in: Journal of personalized medicine (2021)
The research method allowed recording in real time of a larger amount of data from the different components of the spine segment. If there was an extension component of the compression force at the moment of the initial loading, part of this load was absorbed by the posterior column with higher mechanical resistance. After the maximum capacity of the absorption was reached, in both situations the behavior was similar.