Dosimetric Comparison Study of Proton Therapy Using Line Scanning versus Passive Scattering and Volumetric Modulated Arc Therapy for Localized Prostate Cancer.
Masaru TakagiYasuhiro HasegawaKunihiko TateokaYu TakadaMasato HareyamaPublished in: Cancers (2024)
The LS method demonstrated a reduction in rectal and bladder doses relative to PS and VMAT, thereby suggesting the potential for mitigating toxicities.