Partially open stent after balloon catheter iatrogenic perforation. How to solve this complication using a novel technique? The Mij-Her technique.
Roberto Mijangos-VázquezRogelio Hernández-ReyesPublished in: Cardiology in the young (2022)
Complications related to pulmonary artery stenting are potentially life-threatening. We reported a novel technique of how to achieve the introduction of a partial dilated stent into a long sheath using a snare in the event of a iatrogenic perforation of a balloon catheter.There are no publications of similar techniques describing successful resolution of this type of complication.