Hard tissue changes after guided bone regeneration of peri-implant defects comparing block versus particulate bone substitutes: 6-month results of a randomized controlled clinical trial.
Goran I BenicBarbara M EisnerRonald Ernst JungTobias BaslerDavid SchneiderChristoph Hans Franz HämmerlePublished in: Clinical oral implants research (2019)
Block bone substitute used for GBR of peri-implant defects was superior to particulate bone substitute regarding the dimension of the augmented hard tissue after 6 months of healing.