Midterm durability of valve-sparing root replacement in bicuspid and tricuspid aortic valves.
Anthony TranEmily ShihKatherine B HarringtonJustin M SchafferJasjit K BanwaitZuyue WangJ Michael DiMaioMichael J MackWilliam H RyanWilliam T Brinkmannull nullPublished in: Proceedings (Baylor University. Medical Center) (2024)
VSRR can be safely performed on patients with BAV and TAV morphology, yielding similar midterm freedom from mortality, recurrent >2+ AI, and reoperation. This technique should be considered in carefully selected patients with aortic root pathology and BAV anatomy when performed at experienced centers.