Denture bases milled from PMMA blocks showed better adaptation than 3D printed, or wax milled and conventionally fabricated denture bases for both maxillary and mandibular arches. PMMA milling is a reproducible technique that enables the construction of accurate dentures. Clinicians should be cautious about the palatal gap when the compression molding technique is used. Micro-CT is a valid technique for evaluating the denture base adaptation.