Efficacy and safety of the VASCADE® MVP venous vascular closure device in patients undergoing percutaneous left atrial appendage occlusion with WATCHMAN.
Hafez GolzarianKatherine T GraebelRachel BaileyMichael B WidmerArielle ThielGerri HempflingMichael OttoTodd OttoSandeep M PatelPublished in: Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions (2024)
VASCADE MVP significantly reduced TTH compared to Fo8 sutures after LAAO. While demonstrating a similar safety profile, VASCADE MVP may offer a more efficient approach to femoral vein closure in this patient population.