Correction of z-motion artefacts to allow population imaging of synaptic activity in behaving mice.

Thomas Michael RyanAntonio Jesus HinojosaRozan VromanChristoforos PapasavvasLeon Lagnado
Published in: The Journal of physiology (2020)
Functional imaging of head-fixed, behaving mice using two-photon imaging of fluorescent activity reporters has become a powerful tool for studying the function of the brain. Motion artefacts are an inevitable problem during such experiments and are routinely corrected for in x and y dimensions. However, axial (z) shifts of several microns can also occur, leading to intensity fluctuations in structures such as synapses that are small compared to the axial point-spread function of the microscope. Here we present a simple strategy to correct z-motion artefacts arising over the course of a time-series experiment in a single optical plane. Displacement in z was calculated using dye-filled blood vessels as an anatomical marker, providing high contrast images and accuracy to within ∼0.1 µm. The axial profiles of ROIs corresponding to synapses were described using a Moffat function and this 'ROI-spread function' used to correct activity traces on an ROI-by-ROI basis. We demonstrate the accuracy and utility of the procedures in simulation experiments using fluorescent beads and then apply them to correcting measurements of synaptic activity in populations of vasoactive-intestinal peptide (VIP) interneurons expressing the synaptic reporter SyGCaMP6f. Correction of z-motion artefacts had a substantial impact on the apparent correlation between synaptic activity and running speed, demonstrating the importance of correcting these when performing imaging experiments in awake mice.