Discordance between human sperm quality and telomere length following differential gradient separation/swim-up.

Ana Catarina LopesPedro Fontes OliveiraSoraia PintoCarolina AlmeidaMaria João PinhoRosália SáEduardo RochaAlberto BarrosMário Sousa
Published in: Journal of assisted reproduction and genetics (2020)
As the correlations observed in normozoospermic patients were not representative of the whole heterogeneous population, differences in the sperm characteristics of the study population may lead to discrepant results when evaluating the association of STL with sperm quality. Since the total population selected STL was not related with sperm quality and with clinical outcomes, results do not support the use of selected STL measurement to evaluate the reproductive potential of the male patient or to predict the success rates of ART treatments.