First experiences with dynamic renal [ 68 Ga]Ga-DOTA PET/CT: a comparison to renal scintigraphy and compartmental modelling to non-invasively estimate the glomerular filtration rate.
David KerstingMiriam SraiebRobert SeifertPedro Fragoso CostaSandra KazekLukas KesslerLale UmutluWolfgang Peter FendlerWalter JentzenKen HerrmannFlorian BütherMichael NaderChristoph RischplerPublished in: European journal of nuclear medicine and molecular imaging (2022)
Ga]Ga-DOTA PET can be a suitable alternative to conventional scintigraphy. Visual assessment of PET images and conventional renograms revealed comparable results. GFR values derived by non-invasive single-compartmental-modelling of PET data show a good correlation to serum creatinine-derived GFR values. In patients with undisturbed urinary efflux, the correlation was excellent. Dynamic PET data acquisition for 15 min is sufficient for visual evaluation and GFR derivation.