Login / Signup

Validation of ultrasound velocimetry and computational fluid dynamics for flow assessment in femoral artery stenotic disease.

Lennart van de VeldeMajorie van HelvertStefan EngelhardAshkan Ghanbarzadeh-DagheyanHadi MirgolbabaeeJason VoorneveldGuillaume P R LajoinieMichel VersluisMichel M P J ReijnenErik Groot Jebbink
Published in: Journal of medical imaging (Bellingham, Wash.) (2024)
EPIV and CFD-ePIV can accurately measure complex flow features in the femoral bifurcation and around a stenosis. CFD-DUS showed larger deviations in velocities making it a less robust technique for hemodynamical assessment. The applied ePIV and CFD techniques enable two- and three-dimensional assessment of local hemodynamics with high spatiotemporal resolution and thereby overcome key limitations of current clinical modalities making them an attractive and cost-effective alternative for hemodynamical assessment in clinical practice.
Keyphrases
  • clinical practice
  • magnetic resonance imaging
  • computed tomography
  • single molecule