Effects of sterilization, conditioning, and thermal aging on the retention of zirconia hybrid abutments: A laboratory study.
Nalah AlghanaimMatthias KernChristine YazigiMohammed Sad ChaarPublished in: Clinical implant dentistry and related research (2024)
Steam autoclaving increased the retention of hybrid zirconia abutments. DTK adhesive resin for two-piece zirconia abutments performed well after sterilization and thermocycling.