The contralateral oblique fluoroscopic view is associated with a lower incidence of postdural puncture headache in patients undergoing percutaneous spinal cord stimulation.
Elena MadanNasir HussainJatinder S GillThomas T SimopoulosPublished in: Pain practice : the official journal of World Institute of Pain (2023)
The incorporation of the CLO view to guide epidural needle placement can decrease the odds of a PDPH during percutaneous SCS procedures. This study further provides real-world data supporting the potential enhanced accuracy of epidural needle placement in order to avoid unintentional puncture or trauma to deeper spinal anatomic structures.